Dell Poweredge T110 Server Manual

 
Dell Poweredge T110 Server Manual Rating: 4,4/5 4527 votes

Discuss: Dell PowerEdge T110 II Server Series Sign in to comment. Be respectful, keep it civil and stay on topic. We delete comments that violate our policy, which we encourage you to read. Page 1 Dell PowerEdge T110 II Systems Owner’s Manual Regulatory Model E11S Series Regulatory Type E11S002.; Page 2 Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Disclaims any proprietary interest in trademarks and trade names other than its own. Page 1 Dell PowerEdge T110 II Systems Owner’s Manual Regulatory Model E11S Series Regulatory Type E11S002.; Page 2 Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. View and Download Dell PowerEdge T110 hardware owner's manual online. Dell Server Hardware Owner's Manual. PowerEdge T110 Server pdf manual download.

Model Dell PowerEdge T110 II Server - BECT12B2BPS
  1. Dell PowerEdge T310 Technical Guide 7 optional iDRAC Express or iDRAC Enterprise for system alerts, power usage, and select boot-up options. 1.5 Comparison Table 1. Comparison of PowerEdge T310 to T110 II and T410 Feature T110 II T310 T410 Processor Intel® Xeon® processor E3-1200 series Intel Xeon processor E3-1200 V2 product family.
  2. The PowerEdge TM T110 is an Intel processor-based tower server is designed for growing small businesses that need a real server operating system for improved collaboration, better data protection, faster file sharing, easier management, and an easier path for growth.
  3. Search PowerEdge T110 II Documentation Find articles, manuals and more to help support your product. What can we help you to find. Submit Search. Top Solutions Manuals and Documents Regulatory Information Videos Top Solutions. The most helpful knowledge articles for your product are included in this section. Dell PowerEdge T110 II.
  • Dell PowerEdge T110 II Server - BECT12B2BPSBECT12B2BPS
  • Dell PowerEdge T110 II Server - bect12b3b_1bect12b3b1
  • Dell PowerEdge T110 II Server - bect12b3b_6bect12b3b6
  • Dell PowerEdge T110 II Server - BECT12BFSI_1bect12bfsi1
  • Dell PowerEdge T110 II Server - BESW5T2D_1besw5t2d1
  • Dell PowerEdge T110 II Server - BESW5T2D_4besw5t2d4
  • Dell PowerEdge T110 II Server - BECT12B2Bbect12b2b
  • Dell PowerEdge T110 II Server - BECT12B2BMCP_2bect12b2bmcp2
  • Dell PowerEdge T110 II Server - BESW5T7PB_6besw5t7pb6
  • Dell PowerEdge T110 II Server - BESW5T7PB_2besw5t7pb2
  • Dell PowerEdge T110 II Server - BECT12BFSI_3bect12bfsi3
  • Dell PowerEdge T110 II Server - BECT12B2BPS_4bect12b2bps4
  • Dell PowerEdge T110 II Server - BECT12B2BMC_4bect12b2bmc4
  • Dell PowerEdge T110 II Server - BECT12B2BMC2_6bect12b2bmc26
  • Dell PowerEdge T110 II Server - BECT12B2BMC2P_1bect12b2bmc2p1
  • Dell PowerEdge T110 II Server - BECT12BFSI_4bect12bfsi4
  • Dell PowerEdge T110 II Server - BESW5T7PB_5besw5t7pb5
    • Dell PowerEdge T110 II Server - BESW5T7PB_7besw5t7pb7
    • Dell PowerEdge T110 II Server - BECT12BFSI_7bect12bfsi7
    • Dell PowerEdge T110 II Server - BECT12B2BMCP_1bect12b2bmcp1
    • Dell PowerEdge T110 II Server - BESW5T2D_6besw5t2d6
    • Dell PowerEdge T110 II Server - BECT12B2BMC_3bect12b2bmc3
    • Dell PowerEdge T110 II Server - BECT12BFSI_6bect12bfsi6
    • Dell PowerEdge T110 II Server - BECT12B2BMC2_7bect12b2bmc27
    • Dell PowerEdge T110 II Server - BECT12B2BMC2Pbect12b2bmc2p
    • Dell PowerEdge T110 II Server - BECT12B2BMCP_4bect12b2bmcp4
    • Dell PowerEdge T110 II Server - BECT12B2BMC2_5bect12b2bmc25
    • Dell PowerEdge T110 II Server - BECT12B2B_3bect12b2b3
    • Dell PowerEdge T110 II Server - BECT12B2BMCPbect12b2bmcp
    • Dell PowerEdge T110 II Server - BECT12B2BMC2P_2bect12b2bmc2p2
    • Dell PowerEdge T110 II Server - BESW5T2D_2besw5t2d2
    • Dell PowerEdge T110 II Server - BESW5T7PB_1besw5t7pb1
    • Dell PowerEdge T110 II Server - BESW5T7PB_4besw5t7pb4
Rack-mounted 11th-generation PowerEdge servers
Dell

Dell PowerEdge is a server line by Dell, following the naming convention for other Dell products: the PowerVault (data storage) and the PowerConnect (data transfer & switches).

Below is an overview of current and former servers within Dell's PowerEdge product line. Different models are or were available as towers, 19-inch racks or blades. In the current naming scheme, towers are designated by T, racks by R, and blades by M (for modular).[1] The 19' rack-servers come in different physical heights expressed in rack units or U. Most modern servers are either 1U or 2U high while in the past the 4U was more common.

  • 1Model naming

Model naming[edit]

Over the years, many different types of PowerEdge servers have been introduced and there was wide variety of product and family codes used within the PowerEdge name.

Itanium servers[edit]

The Dell Itanium-based servers were introduced before this new naming-convention was introduced and were only available as rack servers.

New naming convention[edit]

Since the introduction of the Generation 10 servers in 2007 Dell has adopted a standardized method for naming their servers; the name of each server is now represented by a letter followed by 3 digits. The letter indicates the type of server: R (for Rack-mountable) indicates a 19' rack-mountable server, M (for Modular) indicates a blade server, whilst T (for Tower) indicates a stand-alone server.[2]

This letter is then followed by 3 digits.

  • The first digit refers to the number of sockets in the system: 1 to 3 for one socket, 4 to 7 for two sockets, and 8 or 9 for four sockets.
  • The middle digit refers to the generation: 0 for Generation 10, 1 for Generation 11, and so on.
  • The third digit indicates the make of the CPU: 0 for Intel or 5 for AMD.

For example: The Dell PowerEdge M610 is a two-socket blade server of the 11th generation using an Intel CPU whilst the R605 is a two-socket AMD-based rack-server of the 10th generation.[1]

Blade servers[edit]

Since Generation 10 there are models for the M1000e enclosure. The blade-servers in Generation 8 and Generation 9 are using another enclosure that is not compatible with the current M1000e system. In form-factor there are two models: half-height and full-height.In an enclosure you can fit 8 full or 16 half-height blades (or a mix). Each server has two or four on-board NIC's and two additional Mezzanine card-slots for additional I/O options: 1 Gb or 10 Gb Ethernet cards, Fibre ChannelHBA's or InfiniBand slots. Apart from USB connectors a blade-server doesn't offer direct connections: all I/O goes via the midplane of the enclosure.

Game gratis download

Early systems[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
SP 433Tower1Intel 80486 33 MHz (P4)EISA/PCI
SP 450Tower1Intel 80486DX2 50 MHz (P24)EISA/PCI
SP 466Tower1Intel 80486DX2 66 MHz (P24)EISA/PCI
SP 560Tower1 Socket 4Pentium 60 60 MHz (P5)EISA/PCI
SP 566Tower1 Socket 4Pentium 66 66 MHz (P5)EISA/PCI
SP 575-2Tower1995[3]1,2 Socket 5Pentium 75 75 MHz (P54C)EISA/PCI
SP 590Tower1994[4]1 Socket 5Pentium 90 90 MHz (P54C)192 MBSIMM8EISA/PCI
SP 590-2Tower1,2 Socket 5Pentium 90 90 MHz (P54C)EISA/PCI
SP 5100[5]Tower1,2Pentium 100 100 MHz (P54C)EISA/PCI
SP 5100-2[5]Tower1,2Pentium 100 100 MHz (P54C)EISA/PCI
SP 5133[5]Tower1,2Pentium 133 133 MHz (P54CS)EISA/PCI
SP 5133-2[5]Tower1,2Pentium 133 133 MHz (P54CS)EISA/PCI
SP 5166[5]Tower1,2Pentium 166 166 MHz (P54CS)EISA/PCI
SP 5166-2[5]Tower1,2Pentium 166 166 MHz (P54CS)EISA/PCI
XE 433Tower1Intel 80486 33 MHz (P4)EISA/PCI
XE 450Tower1Intel 80486DX2 50 MHz (P24)EISA/PCI
XE 466Tower1Intel 80486DX2 66 MHz (P24)EISA/PCI
XE 560Tower1 Socket 4Pentium 60 60 MHz (P5)EISA/PCI
XE 566Tower1 Socket 4Pentium 66 66 MHz (P5)EISA/PCI
XE 575-2Tower1,2 Socket 5Pentium 75 75 MHz (P54C)EISA/PCI
XE 590Tower1,2 Socket 5Pentium 90 90 MHz (P54C)EISA/PCI
XE 590-2Tower1,2 Socket 5Pentium 90 90 MHz (P54C)EISA/PCI
XE 5100Tower1,2Pentium 100 100 MHz (P54C)EISA/PCI
XE 5100-2Tower1,2Pentium 100 100 MHz (P54C)EISA/PCI
XE 5133Tower1,2Pentium 133 133 MHz (P54CS)EISA/PCI
XE 5133-2Tower1,2Pentium 133 133 MHz (P54CS)EISA/PCI
XE 5166Tower1,2Pentium 166 166 MHz (P54CS)EISA/PCI
XE 5166-2Tower1,2Pentium 166 166 MHz (P54CS)EISA/PCI
EL 575TowerPentium 75 75 MHz (P54C)ISA/PCI
EL 590TowerPentium 90 90 MHz (P54C)ISA/PCI
EL 5100TowerPentium 100 100 MHz (P54C)ISA/PCI
EL 5120TowerPentium 120 120 MHz (P54CQS)ISA/PCI
EL 5133TowerPentium 133 133 MHz (P54CS)ISA/PCI
Web ServerTower1995[6]Pentium 133 133 MHz (P54CS)ISA/PCI, based on quad processor EL[6]
XL 5133Tower1-4 (single, quad capable)Pentium 133 133 MHz (P54CS)EISA/PCI
XL 5133-2Tower1-4 (dual, quad capable)Pentium 133 133 MHz (P54CS)EISA/PCI
XL 5133-4[7]Tower1-4 (quad)Pentium 133 133 MHz (P54CS)EISA/PCI
XL 5166Tower1-4 (single, quad capable)Pentium 166 166 MHz (P54CS)EISA/PCI
XL 5166-2Tower1-4 (dual, quad capable)Pentium 166 166 MHz (P54CS)EISA/PCI
XL 5166-4Tower1-4 (quad)Pentium 166 166 MHz (P54CS)EISA/PCI

Generation 1[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
2100[8]Tower1996[9]Intel 440FX1 Socket 8Pentium Pro 180 MHz or 200 MHz256 MB4, 168-pin DIMM
4100[10]Tower2 Socket 8Pentium Pro 180 MHz or 200 MHz1 GB8, 168-pin DIMM
6100[11]Tower4 Socket 8Pentium Pro 200 MHz2 GB16, 72-pin

Generation 2[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
2200[12]Tower2Pentium II, 233 - 333 MHz512 MB4, ECC3 full size SCSI drives (screw in)
4200[13]TowerIntel 440FX2Pentium II 233, 266, 300, or 333 MHz512 MB8, 168-pin EDO DIMM

Generation 3[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
350[14]1U Rackcirca 2001Intel 440BXPentium III 650Mhz-1.0Ghz or
Celeron 600+
1 GB4, SDRAM unbuffered and registered PC-100(2) int. 3.5 ATA-100
(1) slim 3.5' floppy
(1) slim CD-ROM
(2) Intel 82559 10/100
125 W
898 BTU/hr (max)
1300[15]TowerIntel 440BX1Pentium II at 350, 400, or 450 MHz1 GBunbuffered, 72-bit SDRAM or registered, 72-bit SDRAM
2300[16]Tower1998Intel 440BX2Pentium II 333, 350, 400, 450 MHz1 GB4, unregistered PC-100 SDRAM6 Ultra2 SCSI HDD bays
4300[17]7U RackIntel 440GX2Pentium II 350, 400, or 450 MHz1 GB4, 168-pin unbuffered DIMMs or registered DIMMs8 SCSI bays
4350[18]RackIntel 440GX2Pentium II 350, 400, or 450 MHz2 GB
6300[19]Tower4Pentium II Xeon4 GB4, registered EDO DIMM6 Ultra2 SCSI HDD bays
6350[20]4U Rack4Pentium II Xeon at 400 MHz4 GB16, registered EDO DIMM3 HDD bays

Generation 4[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
2400[21]Tower2000[22]2Pentium III 500 MHz minimum2 GB4, registered PC-133 SDRAM6 Ultra2 SCSI HDD bays
2450[23]2U Rack2001[24]2Pentium III 600 MHz minimum2 GB168-pin registered SDRAM 133-MHz
4400[25]7U Rack
or Tower
2Pentium III Xeon, 600 MHz minimum4 GBregistered PC133 SDRAMUp to 10 internal SCSI baysIntroduced circa 1999
6400[26]Tower4Pentium III Xeon, 550 MHz minimum8 GB16, registered PC-133 SDRAM6 or 8 Ultra3 SCSI drivesIntroduced circa 1999
6450[27]4U Rack4Pentium III Xeon 550 MHz8 GB16, registered PC-133 SDRAM4 internal SCSI baysIntroduced circa 1999
8450[28]Rack2000[29]8Pentium III Xeon 500 MHz32 GB168-pin SDRAM 100 MHz

Generation 5[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
1550[30]1U Rack2001[31]ServerWorks HE-SL2Pentium III (933 MHz-1.4 GHz)4, registered PC-133 SDRAM3 hot-swappable Ultra3 SCSI HDD bays
2500[32]Tower or 5U Rack2Pentium III 933 MHz minimum4 GB6, ECC registered PC-133 SDRAM6 hot-swappable Ultra3 SCSI HDD bays, splittable
2550[33]2U Rack2Pentium III 933 MHz minimum4 GBregistered PC133 SDRAM5 internal SCSI baysIntroduced circa 2001

Itanium[edit]

The Itanium line was a separate 'generation' from the traditional server line, but roughly falls between generations 5 and 6.

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
3250[34]2U Rack2003Intel E88702 PAC611Intel Itanium 2 1.5 GHz, 1.3 GHz, 1.4 GHz, 1.0 GHz16 GBDDR SDRAM2 x 1” SCSI drives
7150[35]Rack2001[36]4 PAC418Intel Itanium minimum 733 MHz64 GBPC100 memory4 hotplug SCSI bays
7250[37]Rack2004Intel E88704 PAC611Intel Itanium 232 GBDDR ECC memory3 hotplug SCSI bays

Generation 6[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
650[38]1U Rack20031Pentium 4 up to 3.06 GHz or Celeron up to 1.8 GHz3 GBDDR2× IDE or SCSI
1650[39]1U Rack2002[40]2Pentium III 1.13 GHz+4 GB4, ECC SDRAM 133
1655 MC[41]3U Blade2004ServerWorks ServerSet LE3.02 (per Blade)Pentium III at 1.4 GHz2 GB (per Blade)4, ECC SDRAM 133Houses up to 6 blades
2600[42]Tower or 5U Rack2004Intel E75012 Socket 604Xeon III at 2.4 GHz, 2.8 GHz, 3.06 GHz and 3.2 GHz12 GB6, ECC DDR 2666 HDD bays (SCSI)
2650[43]2U Rack2004ServerWorks GC-LE2 Socket 603Xeon at 2.0 GHz, 2.4 GHz, 2.8 GHz, 3.06 GHz and 3.2 GHz12 GB6, ECC DDR 2665 HDD bays (SCSI)
4600[44]Tower or 6U Rack2003ServerWorks GC-HE2 Socket 603Xeon at 2.4 GHz, 2.6 GHz, 2.8 GHz to 3.0 GHz24 GBECC DDR2 RAM riser cards
6600[45]Tower or 7U Rack2004ServerWorks GC-HE4Xeon MP at 2.0 GHz, 2.2 GHz, 2.7 GHz or 3.0 GHz32 GBECC DDR 2668 SCSI4 RAM riser cards
6650[45]4U Rack2004ServerWorks GC-HE4Xeon MP at 1.4 GHz, 2.0 GHz, 2.2 GHz, 2.7 GHz or 3.0 GHz32 GBECC DDR 2665 SCSI4 RAM riser cards

Generation 7[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
700[46]Tower2004Intel E72101 Socket 478Pentium 4(up to 3.2 GHz/800 MHz) or Celeron (2.4 GHz)4 GBDDR 4004 HDD bays
750[47]1U Rack2005Intel E72101 Socket 478Pentium 4(up to 3.4 GHz/800 MHz) or Celeron (2.4 GHz)4 GBDDR 4002 SCSI or SATA
1750[48]1U Rack2004ServerWorks GC LE2 Socket 604Xeon up to 3.2 GHz8 GB4, DDR 2663 HDD bays (SCSI)

Generation 8[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
800[49]Tower2005Intel E72211 LGA 775Pentium 4 up to 3.8 GHz or Celeron up to 2.53 GHz4 GB4, ECC DDR2 400/5334 × 1' SCSI or SATA
830[50]Tower2005Intel E72301 LGA 775Pentium D up to 3.2 GHz or Pentium 4 up to 3.6 GHz or Celeron D 2.53 GHz8 GB4, ECC DDR2 533-6674 × HDD bays
840
(Gen I, II) [51][52]
Tower2006Intel 30001 LGA 775Xeon X3200 (Gen II only), Xeon 3000, Pentium or Celeron8 GB4, ECC DDR2 533-6672 × 5.25' ext.
1 × 3.5' ext.
4 × 3.5' int. 4 SATA 2 IDE
1800[53]Tower or 5U RackIntel E75202 Socket 604Xeon, 800 MHz FSB12 GB6, ECC DDR26 × HDD bays (SCSI)
1850[54]1U Rack2005Intel E75202 Socket 604Xeon, 800 MHz FSB16 GB6, ECC DDR2 4002 × HDD bays (SCSI)
1855[55]Blade2005Intel E75202 Socket 604Xeon, 800 MHz FSB12 GB6, ECC DDR22 × HDD bays per blade(SCSI)Uses same blade chassis as 1955, up to 10 blades
2800[56]Tower or 5U Rack2005Intel E75202 Socket 604Xeon Single or Dual-core16 GB6, DDR2 4008 to 10 HDD bays (SCSI)
2850[57]2U Rack2005Intel E75202 Socket 604Xeon up to 3.8 GHz or Dual-core Xeon at 2.8 GHz16 GB6, DDR2 4006 × HDD bays (SCSI)
6800[58]Tower2006Intel 85014 Socket 604Xeon 710064 GB16*, ECC DDR210 Hotplug SCSI baysrAM slots only with daughterboard
6850[59]4U Rack2006Intel 85014 Socket 604Xeon 710064 GB16*, ECC DDR25 Hotplug SCSI baysrAM slots only with daughterboard

Generation 9[edit]

ModelChassisYearChipsetCPU SocketsCPURAM (Max)RAM (Type)Drive baysComments
850[60]1U Rack2005Intel E72301 LGA 775Intel Pentium 4 (up to 3.8 GHz) or Celeron (2.53 GHz) or Pentium D dual-core (up to 3.2 GHz)8 GB4, ECC DDR2 533/667 MHz2 × 3.5' SATA or SCSI
860
(Gen I, II) [61][62]
1U Rack2006Intel 30001 LGA 775Celeron D, Pentium D 925, Celeron 430/440, Pentium Dual-Core E2160, Core 2 Duo E4400, Xeon 3000, Xeon 32008 GB4, ECC DDR2 533/667 MHz2 × 3.5' SATA or SAS and 1 × slim opticalThe PE 850 and 860 share chassis with the R200, and other than name badge are visually identical.
1900[63]Tower2006Intel 5000P2 LGA 771Xeon 5000, 5100 or 530016 GB8, DDR2 533/667 MHz FB-DIMM6 × 3.5' SAS/SATA and 1 × Peripheral bay and 1 × 3.5' floppyThis model replaces the 1800. Peripheral bay can hold 2 × 5.25' devices
1950
(Gen I, II, III) [64]
1U Rack2006Intel 5000X2 LGA 771GI: Xeon 5000, 5100
GII: Xeon 5000, 5100, 5300
GIII: Xeon 5000, 5100, 5200, 5300, 5400
GI & GII: 32 GB; GIII: 64 GBGI & GII: 8, ECC DDR2 533/667 MHz FB-DIMM
GIII: 8, ECC DDR2 667 MHz FB-DIMM
2 × 3.5' SAS/SATA or 4 × 2.5' SAS and 1 × slim optical
1955[65]Blade2006Intel 5000P2 LGA 771Xeon 5000, 5100 or 530032 GB8, ECC DDR2 FB-DIMM2 × 2.5' SAS/SATAUses same blade chassis as 1855. Up to 10 blades
2900
(Gen I, II, III) [66]
Tower or 5U2006Intel 5000X2 LGA 771Xeon 5000, 5100, 5300 or 540048 GB12, ECC DDR2 533/667 MHz FB-DIMM8 × 3.5' SAS/SATA and 1 × Flexbay and 1 × Peripheral bay and 1 × 3.5' floppyFlexbay can hold 2 × 3.5' HDD. Peripheral bay can hold 2 × 5.25' devices
2950
(Gen I, II, III) [67][68]
2U Rack2006Intel 5000X2 LGA 771GI: Xeon 5000, 5100
GII: Xeon 5000, 5100, 5300
GIII: Xeon 5000, 5100, 5200, 5300, 5400
GI: 32 GB; GII[69] & GIII: 64 GBGI & GII: 8, ECC DDR2 533/667 MHz FB-DIMM
GIII: 8, ECC DDR2 667 MHz FB-DIMM
8 × 2.5' SAS and 1 × Peripheral bay or 4 × 3.5' SAS/SATA and 1 × Peripheral bay or 6 × 3.5' SAS/SATA and 1 × slim opticalAll configurations include 1 × slim optical drive. Peripheral bay options: Floppy Drive, DAT72 Tape Drive
2970[70]2U Rack2007[71]Broadcom HT-2100 and HT-10002 Socket FOpteron 220032 GB8, ECC DDR2 667 MHz8 × 2.5' SAS/SATA II or 6 × 3.5' SAS/SATA and 1 × Peripheral bay and 1 × slim opticalPeripheral bay options; Floppy Drive, PowerVault 100T Tape Drive
6950[72]4U Rack2006[73]Broadcom HT-2100 and HT-10004 Socket FOpteron 8200 or 830064 GB16, ECC DDR2 667 MHz5 × 3.5' SAS and 1 × slim optical

Generation 10[edit]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
T100[74]Tower2008[75]Intel 32001 LGA 775Xeon 3000, Core 2 Duo 7000, Pentium 2000, Celeron 1200 or Celeron 4008 GB4, ECC DDR2 677-8002 × 3.5' SATA or SAS and 2 × 5.25'
T105[76]Tower2008nVidia CK8-04 Pro1 Socket AM2Opteron 1200, Opteron 1300, Sempron LE12508 GB4, ECC DDR2 677-8002 × 3.5' SATA or SAS and 2 × 5.25'
R200[77]1U Rack2010Intel 32001 LGA 775Xeon 3000, Core 2 Duo, Celeron8 GB4, ECC DDR2 667-800 SDRAM[a]2 × 3.5' non-hot-swap SATA or SAS and 1 × 5.25' removable CD/DVD
T300[78]Tower2007Intel 51001 LGA 771Xeon 5000, Xeon 3000, Core 2 Duo, Celeron24 GB6, ECC DDR2 6674 × 3.5' SATA or SAS
R300[79]1U RackIntel 34001 LGA 771Xeon 5000, Xeon 3000, Core 2 Duo, Celeron24 GB6, ECC DDR2 6672 × 3.5'
M600[80]BladeIntel 5000P2 LGA 771Xeon 500064 GB8, ECC DDR2 667Fits in the M1000E chassis
T605[81]Tower2008[82]Broadcom HT2100 and HT10002 Socket FOpteron 200032 GB8, ECC DDR24 × 3.5' and 1 × 5.25'
M605[83]BladeNVIDIA MCP552 Socket FOpteron 2000, 2200 or 230064 GB8, ECC DDR2 8002 × 2.5' SAS or SATAFits in the M1000E chassis
R805[84]2U Rack2008[85]NVIDIA MCP55Pro + IO-552 Socket FOpteron 2400128 GB16, ECC DDR22 × 2.5' and 1 × slim optical
M805[86]BladeNVIDIA MCP55Opteron 2000128 GB16, ECC DDR2 667-8002 × 2.5' SAS or SSDFits in the M1000E chassis
R900[87]4U RackIntel 73004 Socket 604Xeon 7200, 7300 or 7400256 GB32, FBD DDR2 667-13335 × 3.5' SAS or 8 × 2.5' SAS
R905[88]4U RackBroadcom HT-2100 and HT-11004Opteron 8000256 GB32, ECC DDR28 × 2.5' or 5 × 3.5'EOL : 7/23/2015
M905[89]BladeNVIDIA MCP554Opteron 8000192 GB24, ECC DDR2 667–8002 × 2.5' SAS or SSDFits in the M1000E chassis

Generation 11[edit]

Released by Dell in 2010

ModelChassisYearChipsetCPU

(No. & Socket)

CPU (Type)RAM (Max)RAM (Type)Drive baysComments
T110[90]TowerIntel 34201 LGA 1156Xeon 3400, Celeron G1101, Pentium G6950, Core i3-530 or i3-54016 GB4, U-DIMMs ECC DDR3 1066-13334 × 3.5' SAS or SATA
T110 II[91]Tower2011Intel C2021 LGA 1155Xeon E3-1200 or E3-1200 v2, Celeron G400 / G500, Pentium G600 / G80032 GB4, U-DIMMs ECC DDR3 1066-16004 × 3.5' or 6 × 2.5' SAS or SATA
R210[92]1U RackIntel 34201 LGA 1156Xeon 3400, Celeron G1101, Pentium G6950 or Core i3-50016 GB4, U-DIMMs ECC DDR3 1066-13332 × 2.5' or 2 × 3.5' SAS, SATA or SSD
R210 II[93]1U Rack2011Intel C2021 LGA 1155Xeon E3-1200 or E3-1200 v2, Celeron G400 / G500, Pentium G600 / G80032 GB4, U-DIMMs ECC DDR3 1066-16004 × 2.5' or 2 × 3.5' SAS, SATA or SSD
T310[94]TowerIntel 34001 LGA 1156Xeon 3400, Celeron G1101, Pentium G6950 or Core i3-50032 GB6, R-DIMMs or 4, U-DIMMs, DDR3 800-13334 × 3.5' SAS or SATA
R310[95]1U RackIntel 34201 LGA 1156Xeon 3400, Celeron G1101, Pentium G6950, Core i3-530 or i3-54032 GB6, 1066–13334 × 3.5' or 4 × 2.5” SAS or SATA
T410[96]Tower2009[97]Intel 55002 LGA 1366Xeon 5500 or 5600128 GB8, DDR3 800-13336 × 3.5' and 2 × 5.25' SSD, SAS or SATA
R410[98]1U Rack2009[99]Intel 55002 LGA 1366Xeon 5500 or 5600128 GB8, DDR3 800-13334 × 3.5' or 4 × 2.5'
R415[100]1U RackAMD SR5670 & SP51002 C32Opteron 4100, 4200 or 4300[101]256 GB[102]8, DDR3 1066/13334 × 2.5' or 4 × 3.5' SAS or SATA
R510[103]2U RackIntel 55002 LGA 1366Xeon 5500 or 5600128 GB8, DDR3 800-13334 × 3.5' or 8 × 2.5'/3.5' or 12 × 2.5'/3.5' and 2 × 2.5' internal
r515[104]2U Rack2010AMD SR5670 & SP51002 C32rev I: Opteron 4100; Rev II: 4100 or 4200Opteron 4100: 128 GB; Opteron 4200: 256 GB8, DDR3 1333-160012 × 2.5' or 8 × 3.5'
T610
(Gen I, II) [105]
Tower or 5U RackIntel 55202 LGA 1366Xeon 5500 or 5600192 GB12, RDIMM or UDIMM DDR3 800-1333Up to 8 × 3.5'/2.5' SSD, SAS or SATA
R610
(Gen I, II) [106]
1U RackIntel 55202 LGA 1366Xeon 5500 or 5600384 GB12, DDR3 800-13336 × 2.5' SAS or SSDGen I: No 130W CPUs. 384GB max ram possible with dual CPUs. 192GB max with single CPU.
M610
(Gen I, II) [107]
BladeIntel 55202 LGA 1366Xeon 5500 or 5600192 GB12, ECC DDR32 × 2.5' SAS/SSDFits in the M1000E chassis
T710
(Gen I, II) [108]
Tower or 5U RackIntel 55202 LGA 1366Xeon 5500 or 5600192 GB18, DDR3 800–133316 × 2.5' or 8 × 3.5'
R710
(Gen I, II) [109]
2U Rack2009[110]Intel 55202 LGA 1366Xeon 5500 or 5600288 GB18, DDR3 800-13338 × 2.5' or 6 × 3.5'Gen I: No 130W CPUs [111]
R715[112]2U Rack2010[113]AMD SR5650, SR5670, SP51002 G34Opteron 6100 or 6200256 GB16, DDR3 800–16008 × 2.5' or 6 × 3.5'
M710
(Gen I, II) [114]
BladeIntel 55202 LGA 1366Xeon 5500 or 5600192 GB18, DDR34 × 2.5' SAS or SSDFits in the M1000E chassis
R810 [115][116]2U RackIntel 75004 LGA 1567Xeon 6500 or 75001 TB[117]32, DDR3 10666 × 2.5' SAS, SATA or SATA SSD
R815 [118][119]2U RackAMD SR5650, SR5670, SP51004 G34Opteron 6100512 GB32, DDR3 13336 × 2.5' SAS, SATA or SATA SSD
R910[120]4U RackIntel 75004 LGA 1567Xeon 7500 or E7-4/88002 TB[121]64, DDR3 106616 × 2.5' SAS or SSD
M910[122]BladeIntel 75004 LGA 1567Xeon 6500 or 7500512 GB32, ECC DDR32 × 2.5' SAS or SSDFits in the M1000E chassis
C1100[123]1U RackIntel 55002 LGA 1366Xeon 5500 or 5600192 GB18, ECC DDR3 1066-133310 × 2.5' or 4 × 3.5'
C2100[124]2U RackIntel 55002 LGA 1366Xeon 5500 or 5600192 GB18, ECC DDR3 1066-133312 × 3.5' and 2 × 2.5' internal SATA or SSD
C6100[125]2U RackIntel 55208 LGA 1366Xeon 5500 or 5600768 GB48, DDR3 1066-133324 × 2.5'
or 12 × 3.5'

Generation 12[edit]

In March 2012 Dell introduced their 12th generation servers based on Intel Xeon. There are two basic lines: 620 and 720.[126] On the 720 line, Dell currently offers two rack-model servers: the Poweredge R720 and the R720XD - where the latter offers the option to extend the system to up to 26 internal disks.[127][128]

The Poweredge 620 series offer models for rack, tower and a ½ height blade-server M620.[126] A ½ height blade means that you can fit up to 16 of those servers in one M1000e enclosure. The M520 and M620 can also be used in the new PowerEdge VRTX system. The new M420 is 1/4 height, so 32 fit in a M1000e chassis but does require a special full height holder that fits 4 M420's in one full-height (=double) slot.

For the Generation 12 server-line the out of band server-management system iDRAC received a new version: iDRAC 7. iDRAC allows you to access the server-console via a separate ethernet connection allowing you to get access to the server even when there is no (working) operating system or (normal) network connection available. It offers more or less the same functionality as a network-enabled KVM switch, but with some additional options.

An overview of the offered servers as per July 2012[126]

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM
(Max)
RAM (Type)Internal
Storage (Max)
Drive baysPCI(e) slotsOn board network
T620[129]Tower
rackable, 5U
2012C6002 LGA 2011Xeon E5-2600768 GB24, DIMM
DDR3, 1600Mhz
36 TB8 × 3.5' + 4 × PCIe SSD
or 12 × 3.5'
or 16 × 2.5' + 4 × PCIe SSD
or 32 × 2.5'
7: 4 - x16 FH/FL, 2 - x8 FH/FL, 1 - x8 (x4bw) FH/FLBroadcom or Intel Quad 1 Gb or Dual 10 Gb
R220[130]1U RackC2221 LGA 1150Xeon E3-1200 v332 GB4, DIMM
DDR3, 1600 MHz
2 × 2.5' or 2 × 3.5'1: 1 - x16 FH/FLDual 1Gb
R320[131]1U RackC6021 LGA 1356Xeon E5-2400 or E5-2400 v2 or E5-1400192GB6, DIMM
DDR3, 1600 MHz
16TB8 × 2.5' or 4 × 3.5'2: 1x16 FH/HL, 1x8 HH/HLBroadcom Dual 1Gb
R420[132]1U RackC6022 LGA 1356Xeon E5-2400 or E5-2400 v2384 GB12, DIMM
DDR3, 1600 MHz
16 TB8 × 2.5' or 4 × 3.5'2: 1x16 FH/HL, 1x16 HH/HL (with 2 cpu)

or 2: 1x16 FH/HL, 1x8 HH/HL (with 1 cpu)

Broadcom Dual 1Gb
R620[133]1U Rack2012C6002 LGA 2011Xeon E5-2600
or E5-2600 v2
1.5 TB24, DIMM
DDR3, 1600 MHz
10 TB8 × 2.5' or 4 × 2.5' + 2 × PCIe SSD

or 10 × 2.5'

3: 2 - x16 FH/FL, 1 - x8 FH/FL or
2, 2 x x16
Broadcom or Intel 4× 1Gb or 2× 10Gb
R720[128]2U Rack2012C6002 LGA 2011Xeon E5-2600768 GB24, DIMM
DDR3, 1600Mhz
25 TB8 × 3.5' or 16 × 2.5'7: 1x16 FH/FL, 3x8 FH/FL, 3x8 HH/HLBroadcom or Intel 4× 1Gb or 2× 10Gb
R720XD[127]2U Rack2012C6002 LGA 2011Xeon E5-2600768 GB24, DIMM
DDR3, 1600Mhz
38 TB26 × 2.5' or 12 × 3.5' + 2 × 2.5'6: 2 - x16 FH/FL, 1 - x8 FH/FL, 3 - x8 HH/HLBroadcom or Intel 4× 1Gb or 2× 10Gb
R820[134]2U Rack2012C6004 LGA 2011Xeon E5-46001.5 TB48, DIMM
DDR3 1600 MHz
16 TB16 × 2.5'7: 2 - x16 HL/FH, 1 - x8 HL/FH, 3 - x8 HL/HH, 1 - x8 HL/FH (for RAID controller)Broadcom or Intel 4× 1Gb or 2× 10Gb
R920[135]4U Rack2012C602J4 LGA 2011Xeon E7-4800 v26 TB96, DIMM
DDR3 1600 MHz
28.8 TB24 × 2.5'Broadcom or Intel 4× 1Gb or 2× 10Gb
M420[136]Blade
1/4 height
2012C6002 LGA 1356Xeon E5-2400192 GB6, DIMM
DDR3, 1600Mhz
2 × 200 GB max2 × 1.8'Broadcom[b] 2× 10 Gb LOM +1 Mezzanine slot
M520[137]Blade
1/2 height
2012C6002 LGA 1356Xeon E5-2400384 GB12, DIMM
DDR3, 1600Mhz
2 × SATA/SAS HDD/SSD2 × 2.5'Broadcom or Intel on board+2 Mezzanine slots
M620[138]Blade
1/2 height
2012C6002 LGA 2011Xeon E5-2600768 GB24, DIMM
DDR3, 1600Mhz
2 × 2.5'Broadcom or Intel on board+2 Mezzanine slots
M820[139]Blade
full height
2012C6004 LGA 2011Xeon E5-46001.5 TB48, DIMM
DDR3, 1600 MHz
4 × SAS HDD/SSD
or 2 × PCIe flash SSD
4 × 2.5'2× 10 Gb Converged Ethernet Adaptor on board+2 Mezzanine slots
C6220 [140]2U Rack2012C6008 LGA 2011Xeon E5-26002 TB64, DIMM
DDR3, 1600 MHz
48 TB24 × 2.5' or 12 × 3.5'2× 1Gb LOM, 100 Mb mgt + opt. InfiniBand Mezzanine

Other 12th Generation servers, which are comparable in capabilities with the above detailed M versions of the same model number, are:[141]

  • PE R520 Rackserver
  • PE T320 Tower
  • PE T420 Tower

Dell Poweredge T110 Review

Generation 13[edit]

In September 2014 Dell introduced their 13th generation servers based on Intel Xeon

ModelChassisYearChipsetCPU (No.)CPU (Type)RAM
(Max)
RAM (Type)Internal
Storage (Max)
Drive baysPCI(e) 3.0 slotsOn board network
T130[142]Tower2015Intel C2361Xeon E3-1200 v664 GB4, ECC DDR4 up to 2400 MT/s4 x 3.5” cabled HDD
  • 1x8 PCIe 3.0 (x16 connector)
  • 2x4 PCIe 3.0 (x8 connector)
  • 1x1 PCIe 3.0 (x1 connector)
Broadcom Dual 1Gb
R230[143]1U Rack2015Intel C2361Xeon E3-1200 v564 GB4, DDR4 up to 2133 MT/s
  • 2 x 3.5” cabled HDD
  • 4 x 3.5” cabled HDD
  • 4 x 3.5” hot-swap or 2.5” hot-swap in hybrid drive carrier
2 x PCIe 3.0 slotsBroadcom Dual 1Gb
R330[144]1U Rack2015Intel C2361Xeon E3-1200 v564 GB4, DDR4 up to 2133 MT/s
  • 4 x 3.5” hot-swap
  • 8 x 2.5” hot-swap
2 x PCIe 3.0 slots + 1 slot for internal storage2 x 1Gb
R430[145]1U Rack2014Intel C6101 / 2Xeon E5-2600 v3384 GB12, DDR4 up to 2133 MT/s
  • 20TB (10 × 2.5' SATA HDD)
  • 18TB (10 × 2.5' SAS HDD)
  • 10 x 2.5' HDD: SAS, SATA, NL-SAS, SSD
  • 8 x 2.5' HDD: SAS, SATA, NL-SAS, SSD
2 × x8 HL/HH x16 (2 CPU)
  • 2 x 1Gb
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
R530[146]2U Rack2014Intel C6101 / 2Xeon E5-2600 v3384 GB12, DDR4, up to 2133 MT/s
  • 32TB (8 × 3.5' SATA HDD)
  • 14.4TB (8 × 3.5' SAS HDD)
8 x 3.5' HDD: SAS, SATA, NL-SAS, SSD3 × PCIe3.0 + 2 x PCIe2.0
  • 2 x 1Gb
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
  • up to 8 x 10 Gb + 12 x 1Gb using PCI extension slot
R630[147]1U Rack2014[148]Intel C6102Xeon E5-2600 v3768 GB24, DDR4 up to 2133 MT/s
  • 23TB (24 × 1.8' SSD)
  • 17TB (10 × 2.5' SAS HDD)
  • 14TB (8 × 2.5' SAS HDD)
  • 24 x 1.8' SATA SSD
  • 10 x 2.5' HDD: SAS, SATA, NL-SAS, SSD, 4 NVMe PCIe
  • 8 x 2.5' HDD: SAS, SATA, NL-SAS, SSD
  • 2 × x8 HL/HH x16 + 1 × HL/HH (x16 conn.) (2 CPU)
  • 1 × x16 HL/HH x16 + 1 × .75L/FH (2 CPU)
  • 1 × x16 HL/HH x8 (x16 conn.) + 1 × .75L/FH (1 CPU)
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
T630[149]Tower or 5U Rack2014Intel C6102Xeon E5-2600 v41.5 TB24, DDR4 up to 2133 MT/s
  • 144TB (18 x 3.5' HDD)
  • 72TB (32 x 2.5' HDD)
  • 4 Express Flash PCIe SSDs
  • 8 × 3.5' SAS, SATA, NL-SAS, SSD, PCIe SSD drives with optional flex bay
  • 18 × 3.5' SAS, SATA, NL-SAS, SSD drives
  • 16 × 2.5' SAS, SATA, NL-SAS, SSD, PCIe SSD drives with optional flex bay
  • 32 × 2.5' SAS, SATA, NL-SAS, SSD drives
  • 4 × x16 FL/FH
  • 2 × x8 FL/FH (PCIe 2.0)
  • 1 × x8 HL/FH
  • 1 × x8 HL/FH (PERC)
2 × Intel 1Gb LOM
M630[150]Blade 1/2 height2014Intel C6102Xeon E5-2600 v3768 GB24, DDR4 up to 2133 MT/s
  • 4 × 1.8' SSD
  • 2 × 2.5' PCIe SSD
2 × PCIe 3.0 (x8) mezzanine

(19 different optional adapters available)

R730[151]2U Rack2014Intel C6102Xeon E5-2600 v3768 GB24, DDR4, up to 2133 MT/s
  • 29TB (16 × 2.5' hot-plug SAS)
  • 48TB (8 × 3.5' hot-plug NL SAS)
  • 16 × 2.5' SAS, SATA, NL-SAS, SSD
  • 8 × 3.5' SAS, SATA, NL-SAS, SSD
  • 7 × PCIe 3.0
  • 1 × PERC
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
R730xd[152]2U Rack2014Intel C6102Xeon E5-2600 v3768 GB24, DDR4 up to 2133 MT/s
  • 99.6TB (12 × 3.5' NL SAS HDD/SSD + 4 × 3.5' SAS + 2 × 2.5' SAS HDD/SSD)
  • 68.5TB (18 × 1.8' SATA SSD + 8 × 3.5' SAS HDD)
  • 47.5TB (24 × 2.5' hot-plug SAS HDD + 2 × 2.5' hot-plug SAS HDD)
  • 16 × 3.5' SAS, SATA, NL-SAS, SSD + 2 × 2.5' drives
  • 18 × 1.8' SAS, SATA, NL-SAS, SSD drives + 8 × 3.5' SAS, SATA, NL-SAS, SSD drives, + 2 × 2.5' HDD
  • 26 × 2.5' SAS, SATA, NL-SAS, SSD, PCIe SSD drives
  • 6 × PCIe 3.0
  • 1 × PERC
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
r8302U Rack2016Intel C6122Xeon E5-4600 v43 TB24, DDR4 up to 2400 MT/s61.4TB (16 × 2.5' SSD)16 × 2.5' SAS, SATA, NL-SAS, SSD drives
  • 7 × PCIe 3.0
  • 1 × PERC
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
FC830[153]2U Rack2016Intel C6124Xeon E5-4600 v41.5 TB48, DDR4 up to 2400 MT/s
  • 16 × 1.8' SSD or
  • 8 × 2.5' SSD
  • 4-8 × PCIe 3.0 (x8)
  • 1 × PERC
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
R930[154]4U Rack2015Intel C602J4Xeon E7-4800 v412 TBDDR4 up to 2400 MT/s

Only with daughterboards

  • 99.6TB (12 × 3.5' NL SAS HDD/SSD + 4 × 3.5' SAS + 2 × 2.5' SAS HDD/SSD)
  • 68.5TB (18 × 1.8' SATA SSD + 8 × 3.5' SAS HDD)
  • 47.5TB (24 × 2.5' hot-plug SAS HDD + 2 × 2.5' hot-plug SAS HDD)
  • 16 × 3.5' SAS, SATA, NL-SAS, SSD + 2 × 2.5' drives
  • 18 × 1.8' SAS, SATA, NL-SAS, SSD drives + 8 × 3.5' SAS, SATA, NL-SAS, SSD drives, + 2 × 2.5' HDD
  • 26 × 2.5' SAS, SATA, NL-SAS, SSD, PCIe SSD drives
  • 6 × PCIe 3.0
  • 1 × PERC
  • 4 × 1Gb
  • 2 × 1Gb + 2 × 10Gb
  • 4 × 10Gb
C4130[155]1U Rack2016Intel C6122Intel Xeon E5 2600 v41TB16, DDR4 up to 2400MT/sUp to 4x 2.5' Drives with Tray2x PCIe 3.0 low profile Intel H OmniPath
ModelChassisYearChipsetCPU (No.)CPU (Type)RAM
(Max)
RAM (Type)Internal
Storage (Max)
Drive baysPCI(e) 3.0 slotsOn board network

Poweredge T110 Manual

Generation 14[edit]

In July 2017 Dell EMC introduced their 14th generation servers, adding support for latest Intel Xeon Scalable Processors, better NVM support and other updates.[156]

ModelChassisYearChipsetCPU (No.)CPU (Type)RAM
(Max)
RAM (Type)Internal
Storage (Max)
Drive baysPCI(e) 3.0 slotsOn board network
r2401U Rack2018164GB4, DDR4 up to 2666 MT/s4 x 3.5 SAS, SATA, or SSD2 x 1GbE LOM
r3401U Rack2018164GB4, DDR4 up to 2666 MT/s
  • 8 x 2.5 SAS, SATA, or SSD
  • 4 x 3.5 SAS, SATA, or SSD
2 x 1GbE LOM
r440[157]1U Rack20172Xeon
Bronze 31xx or Silver 41xx or Gold 51xx, 61xx
512 GB16, DDR4 up to 2666 MT/s
  • 40TB (4 x 3.5' hot-plug SAS/SATA HDD/SSD)
  • 48TB (10 x 2.5' hot-plug SAS/SATA HDD/SSD + 4 x NVMe SSD)
  • 2 x M.2 SSD
  • 4 x 3.5' SAS, SATA, NL-SAS, SSD
  • 8 x 2.5' SAS, SATA, NL-SAS, SSD
  • 10 x 2.5' SAS, SATA, NL-SAS, SSD
  • 10 x 2.5' SAS, SATA, NL-SAS, SSD + 4 NVMe SSD
  • 1 x PCIe 3.0 (FH/HL riser)
  • 2 x PCIe 3.0 (HH/HL riser)
  • 2 x 1GbE LOM
  • 2 x 10Gb SFP+
  • 2 x 10GbE
T440[158]Tower or 5U Rack20172Xeon
Bronze 31xx or Silver 41xx or Gold 51xx
512 GB16, DDR4 up to 2666MT/s
  • 96TB (8 x 3.5' hot-plug SAS/SATA HDD/SSD)
  • 61TB (16 x 2.5' hot-plug SAS/SATA HDD/SSD)
  • 2 x M.2 SSD
  • 4 x 3.5' SAS, SATA, NL-SAS, SSD
  • 8 x 3.5' SAS, SATA, NL-SAS, SSD
  • 16 x 2.5' SAS, SATA, NL-SAS, SSD
5 x PCIe 3.02 x 1Gb
T640Tower or 5U Rack20172Intel Xeon scalable3TB24, DDR4 up to 2666MT/s
  • 216 TB
  • 61TB
  • 122TB
  • 112TB
  • 8 or 18 x 3.5” SAS/SATA (HDD/SSD) max 216TB
  • 16 x 2.5” SAS/SATA (HDD/SSD) max 61TB
  • 32 x 2.5” SAS/SATA (HDD/SSD) max 122TB
  • 16 x 2.5 SAS/SATA (HDD/SSD) + 8x NVMe SSD max 112TB
Up to 8 PCIe Gen 32 x 1Gb
r5402U Rack20172Intel Xeon scalable512 GB16, DDR4 up to 2666 MT/s
  • 2 x 1GbE LOM
  • 2 x 10Gb SFP+
  • 2 x 10GbE
R640[159]1U Rack20172Intel Xeon scalable3 TB24, DDR4 up to 2666 MT/s
R740[160]2U Rack2017Intel C62023 TB24, DDR4 up to 2666 MT/s16 x 2.5' SAS/SATA
R740XD[161]2U Rack2017Intel C6202Intel Xeon scalable3 TB24, DDR4 up to 2666 MT/s
R940[162]3U Rack20174Intel Xeon Gold/Platinum6 TB48, DDR4 up to 2666 MT/s
M640
FC640
C6420[163]2U Rack2017
ModelChassisYearChipsetCPU (No.)CPU (Type)RAM
(Max)
RAM (Type)Internal
Storage (Max)
Drive baysPCI(e) 3.0 slotsOn board network

PowerEdge SC Value Servers[edit]

Independent from the main generations of servers a value line was produced.

ModelChassisYearChipsetCPU (No. & Socket)CPU (Type)RAM (Max)RAM (Type)Drive baysComments
300 SC[164]TowerIntel 440BXPentium III1 GB4, ECC reg PC-100
1400 SC[165]Tower20002Pentium III2 GB4, ECC reg PC-133Ultra3 SCSI controller
500 SC[166]Tower2001[167]ServerWorks ServerSet LE 3.01Pentium III 1.0+ or Celeron 800Mhz+2 GB4, ECC PC-133
1500 SC[168]Tower2Pentium III 1.1 GHz4 GB4, ECC reg PC-1336 hot-swappable Ultra3 SCSI HDD bays
600 SC[169]Tower2003ServerWorks GC-SL1Pentium 4 2.0+ or Celeron 1.7+4 GB4, ECC DDR 200
1600 SC[170]Tower2004ServerWorks GC-SL2Xeon at up to 3.2 GHz4 GB4, ECC DDR 266
420 SC[171]Tower2004Intel E72211Pentium 4 or Celeron4 GB4, ECC DDR2 400–533
1420 SC[172]Tower2004Intel E75202 Socket 604Xeon, 800Mhz FSB8 GB6, ECC DDR2-400(3) internal 3.5'
(2) 5.25 external
up to 4 HDD
1425 SC[173]1U RackIntel E75202Xeon, 800Mhz FSB12 GB6, ECC DDR2 400up to 4 HDD
430 SC[174]Tower2005Intel E72301 LGA 775Pentium 4 or Celeron D4 GB4, ECC DDR2 533(2) ext. 5.25'
(1) ext. 3.5'
(2) int. 3.5'
1430 SC[175]Tower2006Intel 5000V2 LGA 771Xeon 5300, Xeon 5100, Xeon 500016 GB4, ECC DDR2 533-667 MHz4 3.5' SAS or SATA
1435 SC[176]1U Rack2007Broadcom HT-2100 and HT-10002 Socket FOpteron 2200 or 230032 GB8, ECC DDR2 6671 slimline bay
440 SC[177]Tower2006Intel 30001Xeon 3000, Pentium D or Celeron D8 GB4, ECC DDR2 533–6672 3.5' SATA or SAS 2 5.25'Although Dell's literature says the max RAM is 4GB, several people have had success running it with 8GB RAM total

Notes[edit]

Dell Poweredge T110 Server

References[edit]

  1. ^ abServerwatch website Spotlight on Dell, 15 May 2008, visited 28 June 2011
  2. ^Infoworld website Dell revamps Poweredge line, 12 November 2007, visited 28 June 2011
  3. ^Dornbusch, Margaret (May 1, 1995). 'Bevy of new servers spring up'. Network World. Framingham, Massachusetts: IDG Network World. 12 (18): 23. ISSN0887-7661.
  4. ^'Benchmark Tests: File Servers'. PC Magazine. Ziff Davis, Inc. 13 (17): 218. October 11, 1994.Benchmark Tests: File Servers
  5. ^ abcdefDell PowerEdge SP 5100-2/5133-2/5166-2 manual
  6. ^ abDeVoe, Deborah (November 20, 1995). 'Dell joins Internet parade with Web server'. InfoWorld. San Francisco, California: InfoWorld Media Group. 17 (47): 6. ISSN0199-6649.
  7. ^Dell PowerEdge XL 5133-4 manual
  8. ^Dell PowerEdge 2100 Service ManualArchived 2012-03-13 at the Wayback Machine
  9. ^PC Pro review of the Dell PowerEdge 2100/180
  10. ^Dell PowerEdge 4100 User GuideArchived 2010-08-27 at the Wayback Machine
  11. ^Dell PowerEdge 6100 User GuideArchived 2012-03-13 at the Wayback Machine
  12. ^Dell PowerEdge 2200 User GuideArchived 2012-03-13 at the Wayback Machine
  13. ^Dell PowerEdge 4200 SpecificationsArchived 2010-11-17 at the Wayback Machine
  14. ^Dell PowerEdge 350 Technical SpecificationArchived 2012-01-05 at the Wayback Machine
  15. ^Dell PowerEdge 1300 Technical Specifications
  16. ^Dell PowerEdge 2300 Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  17. ^Dell PowerEdge 4300 Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  18. ^Dell PowerEdge 4350 User GuideArchived 2012-03-28 at the Wayback Machine
  19. ^Dell PowerEdge 6300 Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  20. ^Dell PowerEdge 6350 Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  21. ^Dell PowerEdge 2400 Technical SpecificationsArchived 2011-01-03 at the Wayback Machine
  22. ^PC Pro review of the Dell PowerEdge 2400
  23. ^Dell PowerEdge 2450 Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  24. ^PC Pro review of the Dell PowerEdge 2450
  25. ^Dell PowerEdge 4400 Technical SpecificationsArchived 2011-06-23 at the Wayback Machine
  26. ^Dell PowerEdge 6400 Technical SpecificationsArchived 2012-03-11 at the Wayback Machine
  27. ^Dell PowerEdge 6450 Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  28. ^Dell PowerEdge 8450 Technical Specifications
  29. ^Novell, Dell PowerEdge 8450 Netwear test report
  30. ^Dell PowerEdge 1550 Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  31. ^PC Pro review of the Dell PowerEdge 1550Archived 2010-11-18 at the Wayback Machine
  32. ^Dell PowerEdge 2500 Technical SpecificationsArchived 2010-10-09 at the Wayback Machine
  33. ^Dell PowerEdge 2550 Technical SpecificationsArchived 2012-01-11 at the Wayback Machine
  34. ^Dell PowerEdge 3250 Specification Sheet
  35. ^Dell PowerEdge 7150 Technical SpecificationsArchived 2010-04-12 at the Wayback Machine
  36. ^PC Pro review of the Dell PowerEdge 7150
  37. ^Dell PowerEdge 7250 Specification Sheet
  38. ^Dell PowerEdge 650 Specification Sheet
  39. ^Dell PowerEdge 1650 Technical Specifications
  40. ^Novell, Dell PowerEdge 1650 Netware test report
  41. ^Dell PowerEdge 1655MC Specification Sheet
  42. ^Dell PowerEdge 2600 Specification Sheet
  43. ^Dell PowerEdge 2650 Specification Sheet
  44. ^Dell PowerEdge 4600 Specification Sheet
  45. ^ abDell PowerEdge 66X0 Specification Sheet
  46. ^Dell PowerEdge 700 Specification Sheet
  47. ^Dell PowerEdge 750 Specification Sheet
  48. ^Dell PowerEdge 1750 Specification Sheet
  49. ^Dell PowerEdge 800 Specification Sheet
  50. ^Dell PowerEdge 830 Specification Sheet
  51. ^Dell PowerEdge 840 Specification Sheet
  52. ^PowerEdge 840 A08 BIOS Release Notes
  53. ^Dell PowerEdge 1800 Technical Specifications
  54. ^Dell PowerEdge 1850 Specification Sheet
  55. ^Dell PowerEdge 1855 Specification Sheet
  56. ^Dell PowerEdge 2800 Specification Sheet
  57. ^Dell PowerEdge 2850 Specification Sheet
  58. ^Dell PowerEdge 6800 Specification Sheet
  59. ^Dell PowerEdge 6850 Specification Sheet
  60. ^Dell PowerEdge 850 Info brief
  61. ^Dell PowerEdge 860 Specification Sheet
  62. ^PowerEdge 860 A05 BIOS Release Notes
  63. ^Dell PowerEdge 1900 Specification Sheet
  64. ^Dell PowerEdge 1950 Specification Sheet
  65. ^Dell PowerEdge 1955 Specification Sheet
  66. ^Dell PowerEdge 2900 Specification Sheet
  67. ^Dell PowerEdge 2950 Specification Sheet
  68. ^Dell PowerEdge 2950 III Specification Sheet
  69. ^Dell PowerEdge 1950/2950 Memory Capacity
  70. ^Dell PowerEdge 2970 Specification Sheet
  71. ^PC Pro Review of the Dell Power PowerEdge 2970
  72. ^Dell PowerEdge 6950 Specification Sheet
  73. ^PC Pro Review of the Dell Power PowerEdge 6950
  74. ^Dell PowerEdge T100 Specification Sheet
  75. ^PC Pro review of Dell PowerEdge T100
  76. ^Dell PowerEdge T105 Specification Sheet
  77. ^Dell PowerEdge R200 Specification Sheet
  78. ^Dell PowerEdge T300 Specification Sheet
  79. ^Dell PowerEdge R300 Specification Sheet
  80. ^Dell PowerEdge M600 Blade Server
  81. ^Dell PowerEdge T605 Specification Sheet
  82. ^PC Pro review of Dell PowerEdge T605
  83. ^Dell PowerEdge M605/E1000E Specification Sheet
  84. ^Dell PowerEdge R805 Specification Sheet
  85. ^PC Pro review of Dell PowerEdge R805
  86. ^Dell PowerEdge M805 Specification Sheet
  87. ^Dell PowerEdge R900 Specification Sheet
  88. ^Dell PowerEdge R905 Specification Sheet
  89. ^Dell PowerEdge M905 Specification Sheet
  90. ^Dell PowerEdge T110 Specification Sheet
  91. ^Dell PowerEdge T110 II Specification Sheet
  92. ^Dell PowerEdge R210 Specification Sheet
  93. ^Dell PowerEdge R210 II Specification Sheet
  94. ^Dell PowerEdge T310 Specification Sheet
  95. ^Dell PowerEdge R310 Specification Sheet
  96. ^Dell PowerEdge T410 Specification Sheet
  97. ^PC Pro review of Dell PowerEdge T410
  98. ^Dell PowerEdge R410 Specification Sheet
  99. ^PC Pro review of Dell PowerEdge R410
  100. ^Dell PowerEdge R415 Specification Sheet
  101. ^https://www.dell.com/support/article/nz/en/nzdhs1/sln155889/memory-information-for-11th-generation-amd-processor-servers?lang=en
  102. ^https://www.dell.com/support/article/nz/en/nzdhs1/sln155889/memory-information-for-11th-generation-amd-processor-servers?lang=en
  103. ^Dell PowerEdge R510 Specification Sheet
  104. ^Dell PowerEdge R515 Specification Sheet
  105. ^Dell PowerEdge T610 Specification Sheet
  106. ^Dell PowerEdge R610 Specification Sheet
  107. ^Dell PowerEdge M610 Specification Sheet
  108. ^Dell PowerEdge T710 Specification Sheet
  109. ^Dell PowerEdge R710 Specification Sheet
  110. ^PC Pro review of Dell PowerEdge R710
  111. ^Dell PowerEdge R710 System Boards (Motherboards)
  112. ^Dell PowerEdge R715 Specification Sheet
  113. ^PC Pro review of Dell PowerEdge R715
  114. ^Dell PowerEdge M710 Specification Sheet
  115. ^Dell PowerEdge R810 Specification Sheet
  116. ^Stevens, Alan (June 25, 2010). 'Dell PowerEdge R810'. ZDNet. Retrieved March 7, 2012.
  117. ^Dell PowerEdge R810 System Memory Update
  118. ^Dell PowerEdge R815 Specification Sheet
  119. ^Dignan, Larry (March 30, 2010). 'Dell PowerEdge R815'. ZDNet. Retrieved April 13, 2012.
  120. ^Dell PowerEdge R910 Specification Sheet
  121. ^'dell R910 spec'(PDF).
  122. ^Dell PowerEdge M910 Specification Sheet
  123. ^Dell PowerEdge C1100 Specification Sheet
  124. ^Dell PowerEdge C2100 Specification Sheet
  125. ^Dell PowerEdge C6100 Specification Sheet
  126. ^ abcOverview page about the Poweredge 12th generation servers, visited 7 March 2012
  127. ^ abDell website with specifications on the Poweredge R720XD, visited 7 March 2012
  128. ^ abDell website with specifications on the Poweredge R720, visited 7 March 2012
  129. ^Dell website: Poweredge T620 Technical specifications, visited 7 March 2012
  130. ^Dell website: Poweredge R220 Technical specifications, visited 2 October 2014
  131. ^Dell website: Poweredge R320 Technical specifications, visited 24 March 2016
  132. ^Dell website: Poweredge R420 Technical specifications, visited 2 October 2014
  133. ^Dell website: Poweredge R620 Technical specifications, visited 7 March 2012
  134. ^Dell website: Poweredge PowerEdge R820 rack server details, visited 06 February 2012
  135. ^Dell website: Poweredge PowerEdge R920 rack server details, visited 05 May 2019
  136. ^Dell website: Poweredge M420 Technical specifications, visited 17 July 2012
  137. ^Dell website: Poweredge M520 Technical specifications, visited 28 July 2012
  138. ^Dell website: Poweredge M620 Technical specifications, visited 7 March 2012
  139. ^Dell website: Poweredge M820 Technical specifications, visited 28 July 2012
  140. ^Dell website: Poweredge C6220 Technical specifications, visited 28 July 2012
  141. ^Overview 12th Generation servers, Dell website. Visited 28 July 2012
  142. ^Dell PowerEdge T130 Specification Sheet
  143. ^Dell PowerEdge R230 Specification Sheet
  144. ^Dell PowerEdge R330 Specification Sheet
  145. ^Dell PowerEdge R430 Specification Sheet
  146. ^Dell PowerEdge R530 Specification Sheet
  147. ^Dell PowerEdge R630 Specification Sheet
  148. ^Dell 13th Generation PowerEdge Server Resources, Dell website. Visited 17 February 2015
  149. ^Dell PowerEdge T630 Specification Sheet
  150. ^Dell PowerEdge M630 Specification Sheet
  151. ^Dell PowerEdge R730 Specification Sheet
  152. ^Dell PowerEdge R730xd Specification Sheet
  153. ^'Dell PowerEdge FC830 SpecSheet'(PDF). dell.com.
  154. ^Dell PowerEdge R930 Specification Sheet
  155. ^Dell EMC PowerEdge C6420 Specification Sheet
  156. ^Press Release about 14th generation
  157. ^Dell EMC PowerEdge R440 Specification Sheet
  158. ^Dell EMC PowerEdge T440 Specification Sheet
  159. ^Dell EMC PowerEdge R640 Specification Sheet
  160. ^Dell EMC PowerEdge R740 Specification Sheet
  161. ^Dell EMC PowerEdge R740XD Specification Sheet
  162. ^Dell EMC PowerEdge R940 Specification Sheet
  163. ^Dell EMC PowerEdge C6420 Specification Sheet
  164. ^Dell PowerEdge 300 Technical SpecificationArchived 2012-03-28 at the Wayback Machine
  165. ^Dell PowerEdge 1400SC Technical SpecificationsArchived 2012-03-28 at the Wayback Machine
  166. ^Dell PowerEdge 500SC Technical Specification
  167. ^PC Mag review of the Dell PowerEdge 500SC
  168. ^Dell PowerEdge 1500SC Technical Specifications
  169. ^Dell PowerEdge 600SC Specification Sheet
  170. ^Dell PowerEdge 1600SC Specification Sheet
  171. ^Dell PowerEdge SC420 Specification Sheet
  172. ^Dell PowerEdge SC1420 Specification Sheet
  173. ^Dell PowerEdge SC1425 Technical Specifications
  174. ^Dell PowerEdge SC430 Specification Sheet
  175. ^Dell PowerEdge SC1430 Specification Sheet
  176. ^Dell PowerEdge SC1435 Specification Sheet
  177. ^Dell PowerEdge SC440 Specification Sheet

External links[edit]

Wikimedia Commons has media related to Dell PowerEdge.

Dell Poweredge T110 Server Manual Pdf

Retrieved from 'https://en.wikipedia.org/w/index.php?title=List_of_Dell_PowerEdge_Servers&oldid=918084264'